EasyManua.ls Logo

LS Starvert SV-iC5 - How to Enable Sensorless Vector Mode

LS Starvert SV-iC5
15 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Easy Start Guide
8. How to enable Sensorless Vector Mode
LS Industrial Systems SV-iC5
Page 9
This guide has been produced by The Inverter Drive Supermarket Ltd.
All content, including but not limited to graphics, text and procedures copyright The Inverter
Drive Supermarket and must not be reproduced or altered without prior written permission.
©
The standard operating mode of the iC5
Inverter is VxF. This is the simplest form of
operation and controls Volts and Frequency to
vary the speed of a standard Induction Motor.
The iC5 can also operate in Sensorless Vector
mode. This can improve motor performance
without requiring a separate feedback device.
Sensorless Vector mode operates in the same
way as VxF but performs a number of
calculations to improve low speed torque.
This requires an “ID” run during which the
Inverter runs the motor for approx. 1 minute at
various speeds to gather the necessary data.
Decouple the motor from the machine
before starting an ID run.
Parameter
Description
How to set
H40
Control Mode
Default is 0. Change to 3 to enable Sensorless Vector Mode.
H41
Auto-tuning
Default is 0. Ensure motor is off-load before changing to 1 to begin ID run.
8.1 Parameters in Function Group 2 - “H”
Press left/right to find H0 then up/down to find parameter number

Related product manuals