Chapter 3 Before positioning 
 
3- 33 
•M code output mode set in the parameter is applied to all operation step of each axis. 
•The user can select one M code output mode among three modes, NONE, WITH, AFTER. 
According to each setting value, timing of M code output signal is as follows. 
 
(a) NONE mode   
 •In case M code output mode is selected as NONE, though M code is set in operation data, M 
code doesn’t occur like the following figure. 
•If the user use this function, it can prohibit the M code function set per operation step, 
simultaneously. 
 
 
(b) WITH mode   
      • In case M code output mode is set as WITH, like the following figure, it outpus M code on signal 
and M code number when each step runs.   
 
 
     < M code output timing in case of WITH mode > 
 
(c) AFTER mode   
      • In case M code output mode is set as AFTER, like the following figure, if each operation of step 
is completed, it outputs M code On signal and M code number.