EasyManua.ls Logo

LSIS XEC-DN60SU - User Manual

LSIS XEC-DN60SU
315 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Loading...
Right choice for ultimate yield
LSIS strives to maximize customers' profit in gratitude of choosing us for your partner.
Programmable Logic Controller
XGB Built-in Positioning
Users Manual
Read this manual carefully before
installing,
wiring, operating, servicing
or inspecting this equipment.
Keep this manual within easy reach
for quick reference.
XEC-DN20SU
XEC-DN30SU
XEC-DN40SU
XEC-DN60SU
XEC-DP20SU
XEC-DP30SU
XEC-DP40SU
XEC-DP60SU
XEC-DN32H
XEC-DN64H
XEC-DP32H
XEC-DP64H
XGT Series
http://eng.lsis.biz
XBM-DN16S
XBM-DN32S
XBC-DN20S(U)
XBC-DN30S(U)
XBC-DN40SU
XBC-DN60SU
XBC-DP20SU
XBC-DP30SU
XBC-DP40SU
XBC-DP60SU
XBC-DN32H(/DC)
XBC-DN64H(/DC)

Table of Contents

Questions and Answers

  • T
    troy33Aug 16, 2025
    What to do if PWR LED is off on LSIS Controller?
    • D
      David TapiaAug 16, 2025
      If the PWR LED is off on your LSIS Controller, first verify that the rated voltage is being supplied to the PLC. If the voltage supply is normal, it may indicate a hardware problem. Contact an A/S office or customer center for assistance.
  • K
    kaylalaneAug 22, 2025
    How to fix ERR LED flashing quickly on LSIS XEC-DN60SU Controller?
    • D
      David MarquezAug 22, 2025
      When the ERR LED is flashing quickly on the LSIS Controller, it indicates a serious problem that prevents operation. Access the XGB with XG5000, go to ‘Online’ -> ‘PLC error/warning’, then check the error and warning messages, and resolve the underlying cause.
  • T
    Todd WoodAug 25, 2025
    Why is RUN LED off on LSIS Controller?
    • J
      john36Aug 25, 2025
      If the RUN LED is off on your LSIS Controller, it means that the program has stopped running. Check the ERR LED to determine if the program stopped due to an error or because the operation mode is set to STOP.
  • J
    Johnny HarrisAug 28, 2025
    What to do if Positioning Output LED is off on LSIS XEC-DN60SU?
    • E
      Erin WilliamsAug 28, 2025
      If the Positioning Output LED is off on the LSIS Controller, it indicates that the pulse is not being output normally, or the positioning operation has finished normally. If the operation finished normally, start the next operation instruction. If there is an error, check the positioning error code and resolve the cause.
  • C
    Carl RogersAug 31, 2025
    What does it mean when ERR LED is on LSIS XEC-DN60SU Controller?
    • M
      Michael OsbornAug 31, 2025
      If the ERR LED is on for the LSIS Controller, there is a problem with the PLC hardware. Contact an A/S office or customer center for assistance.
  • B
    beth02Sep 3, 2025
    Why is Positioning Output LED fast flashing on LSIS XEC-DN60SU Controller?
    • A
      Andre PaceSep 3, 2025
      If the Positioning Output LED is flashing quickly, it means the pulse is being normally output by the positioning function. Check the lines of the XGB and motor driver to ensure there are no issues.
  • M
    Maria ScottSep 6, 2025
    What does it mean when PWR LED is on LSIS Controller?
    • N
      Nicole ElliottSep 6, 2025
      If the PWR LED is on for the LSIS Controller, the power supply is normal. Check whether there is another cause for the issue you are experiencing.
  • M
    Michael Carroll MDSep 8, 2025
    What does Direction Output LED On (HIGH Active) mean on LSIS XEC-DN60SU?
    • T
      Thomas PotterSep 9, 2025
      If the Direction Output LED is on (HIGH Active) for the LSIS controller, it means that direction signals are being output in the reverse direction, or the positioning operation has finished normally. Start the next operation instruction. If there is an error that makes positioning operation impossible, check the positioning error code and remove the cause.
  • D
    David WrightSep 10, 2025
    What to do if PWR LED is flashing on LSIS Controller?
    • J
      John GreenSep 12, 2025
      If the PWR LED is flashing on your LSIS Controller, check the voltage and current of the power supply. If the problem persists, remove the input and output lines, re-supply power, and check again. If the problem continues, contact the A/S office or customer center.
  • A
    Andrew HowellSep 12, 2025
    What does it mean when RUN LED is on LSIS XEC-DN60SU?
    • V
      vweberSep 12, 2025
      If the RUN LED is on for the LSIS Controller, it means the program is operating normally. Check whether there is another cause for any issues you might be experiencing.

Summary

XGB Built-in Positioning Users Manual

Safety Instruction

Essential safety guidelines for operating and handling the equipment.

Chapter 3 Before Positioning

Covers essential steps and parameters required before starting positioning operations.

Chapter 5 Positioning Instructions

Explains the definitions, functions, and usage of various positioning instructions.

Chapter 8 Troubleshooting Procedure

Guides users on identifying and resolving common errors and malfunctions.

Appendix 2 Positioning Instruction and K area List

Lists and describes positioning instructions and their corresponding K area addresses.

Safety Instruction

Safety Instructions when designing

Safety precautions and guidelines for designing the system with the product.

Safety Instructions when wiring

Guidelines for safe and correct wiring procedures to prevent hazards.

Chapter 2 General Specification

Chapter 3 Before Positioning

3.1 Positioning Function

Lists and describes various positioning functions like position control and speed control.

3.2 Positioning Parameter

Details the sequence for setting positioning parameters and K area configuration.

Chapter 5 Positioning Instructions

5.2 Details of Positioning Instructions

Provides detailed descriptions and examples of various positioning instructions.

5.3 Positioning Function Blocks (for XEC)

Explains general function blocks and common error codes for XEC PLC.

Chapter 8 Troubleshooting Procedure

8.2 Check by Using the LED

Describes how to check PLC status using LEDs for troubleshooting.

8.3 Check by Error Code

Guides on checking and removing causes of errors using error codes.

Appendix 1 List of Error Codes

1.2 List of Positioning Error Codes

Details error codes specific to the XGB positioning function.

Appendix 2 Positioning Instruction and K area List

Appendix 3 Motor Wiring Example

LSIS XEC-DN60SU Specifications

General IconGeneral
ModelXEC-DN60SU
CategoryController
SeriesXEC
Power Supply24V DC
Digital Inputs36
Digital Outputs24
Output TypeTransistor
Programming SoftwareXG5000
Operating Temperature0°C to 55°C
Storage Temperature-20°C to 70°C
Humidity5% to 95% RH (non-condensing)
Protection ClassIP20
Product TypePLC
Communication PortsEthernet, RS-232, RS-485