LTSscale.com Page 24 of 28 REV F 2018.04.09
LTS DR2100A/AN Indicator
Out-of-Level Calibration
This procedure is to calibrate the DR2100AN indicator with a Clinometer for Out-of-Level weighing. The
scale base and DR2100AN indicator should be installed per the installation instructions prior to performing
this procedure. Out-of-Level calibration should be done after installation and before unit is placed into
service.
Warning: Once this procedure has been started it MUST be completed in all 4 directions. Before
starting, read through this procedure completely. Make sure you understand the
procedure and can tip the mast 3 degrees in all directions.
1.18. Apply power to the indicator. Allow 15-20 minutes for warm up.
1.19. Remove the cover from the back of the indicator.
1.20. Press keys 9092. Press ENTER key.
Top display line shows the gross weight.
Bottom display line shows: FB (front-to-back) angle
LR (left-to-right) angle.
No load should on the scale at this time.
Note: The clinometer is mounted on top of the scale base.
All references to the position of the truck while calibrating
are made while sitting in the driver seat.
1.21. Level truck so both FB and LR angles are within 0.0° +/- 0.2°.
Level is obtained by tilting forks for Front-to-Back
And moving to a flat location or tip truck for Left-to-Right.
Move truck, (level condition) until: FB = +0.0° (+/- 0.2°)
LR = +0.0° (+/- 0.2°)
1.22. Press DEL key.
Note: DO NOT select “YES”. Angle zero has been set at the factory.
Do not change any of the numbers in the following steps unless instructed.
1.23. Press ENTER key.
1.24. Press ENTER key.
1.25. Press ENTER key.
1.26. Press ENTER key.
1.27. Press ENTER key.
1.28. Press ENTER key.
1.29. Press keys 9094. Press ENTER key.
1.30. Press DEL key to place the asterisk next to YES.
Press ENTER key.
1.31. Key in the value of the test weight to be used.
Press ENTER key.
GROSS = 0
FB= X.X LR= X.X
GROSS = 0
FB=+0.0 LR= +0.0
SET ANGLE ZERO
YES *NO
FB ANGLE ZERO
NUMBER = XXX
LR ANGLE ZERO
NUMBER = XXX
FB ANGLE SPAN
FACTOR = XXX
LR ANGLE SPAN
FACTOR = XXX
FRONT TO FRONT
YES *NO
CALIB ANGLE FTRS
YES *NO
TEST LOAD VALUE
WEIGHT = XXXXX