EasyManua.ls Logo

Lufft SHM31 - ASCII Command Overview

Lufft SHM31
66 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Communication over UMB-ASCII 2.0
Snow depth sensor SHM 31, V2.1 31
R
emark: In the Bray terminal program hex values are transferred with a leading $ character,
ASCII-codes with a # character.
8.
7. ASCII command overview
Command
UMB-ASCII 2.0
Standard
value
Read, write,
command
Name Description
IFO R Info
Query of the sensor
information
SI RW Stations-ID Stations-ID
NAM R Name
SRN
R
Serial number
Lufft serial number
DSC
R
Description
Description
Table 6: Sensor information
Query of the sensor information (IFO). From parameter 20 on a valid channel number has to be
included as a second parameter.
Examples
B001:4E:IFO;12 transmits the version number, or
B001:4E:IFO;20;100 transmits the name of UMB channel 100
Li
st of currently included parameters:
• 10 ASCII2_INFO_NAME
• 11 ASCII2_INFO_DESC
• 12 ASCII2_INFO_VER
• 13 ASCII2_INFO_EXT
• 14 ASCII2_INFO_E2SIZE
• 1
5 ASCII2_INFO_NUMBEROFCHANNELS
• 16 ASCII2_INFO_CHANNELNUMBERS* (starting FW 1.3)
• 20 ASCII2_INFO_CHAN_NAME
• 21 ASCII2_INFO_CHAN_RANGE
• 22 ASCII2_INFO_CHAN_UNIT
• 23 ASCII2_INFO_CHAN_DATATYPE
• 24 ASCII2_INFO_CHAN_TYPE
• 30 ASCII2_INFO_CHAN_INFO
*
) Remark: requires an additional parameter which defines which part (block) of the channels should be
transmitted. There are 4 blocks for the SHM31. Example: ...IFO;16;0
Command
UMB-ASCII 2.0
Standard
value
Read, write,
command
Name Description
MEN C
MeasurementEnd
Cancels the current measurement, and
the calculation and transmission of
telegrams

Table of Contents