22
ContactanauthorisedLUKASdealerortheLUKASCustomerServiceDepartmentdirectly
ifthemalfunctionscannotberectied!
TheaddressfortheLUKASCustomerServicedepartmentis:
LUKAS
Hydraulik GmbH
Weinstrasse39, D-91058Erlangen,Germany
POBox2560 D-91013Erlangen
Tel.: (+49)09131/698-348
Fax.: (+49)09131/698-353
Fault Check Cause Solution
Hoselinecannot
becoupled
Checkthatthe
pressurereliefvalve
onthehandpumpis
open.
Pressureistoohigh. Openthepressure
reliefvalveonthe
handpump.
Couplingdefective Couplingmustbe
replacedimmediately
Hydraulicuid
leakonthehose
lineoritsinserts
Arethehosesdefec-
tive?
Leak,possibledam-
age
Replacehoseline.
Damageonthe
surfaceofthe
hoseline
Checkhoselinefor
externaldamage.
Mechanicaldamage
orcontactwithag-
gressiveagents
Replacehoseline.
Leakonthecou-
plings
Isthecouplingdam-
aged?
Couplingdefective Couplingmustbe
replacedimmediately