EasyManua.ls Logo

Lukas S 312 E2 - Troubleshooting

Default Icon
40 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
26
10. Troubleshooting
Fault Check Cause Solution
Themotordoesnot
startafteractivating
thestargrip.
Themainswitch
isnotilluminated,
althoughithasnot
beenswitchedo󰀨.
Thestargripwas
notusedforsome
time(atleast10
minutes)during
batteryoperation.
Therechargeable
batteryhas
switcheditselfo󰀨.
Inordertoresume
workwiththedevice,
theeDRAULIC
devicemustrst
beswitchedo󰀨at
themainsandthen
switchedonagain.
Alternatively,the
capacitydisplayon
therechargeable
batterycanbe
activatedorthe
batterymaybe
brieyunplugged
andreplugged
again.
Bladearmsmove
slowlyorjerkily
whenoperated
Batteryfully
charged?
Batteryat Chargebattery
Batterydefective Replacebattery
Airinthehydraulic
system
Repairbyan
authorizeddealer,by
personnelspecially
trainedbyLUKAS,
orbyLUKASitself
Powersupplycable
connected?
Powersupply
notproperly
connectedtothe
eDRAULICdevice
(notautomatically
locked).
Reinsertpower
supplyintothe
connectionshaft
Powersupply
cablenotproperly
connectedtothe
externalpower
supply.
Reconnectexternal
powersupply
Powersupplyor
powersupplycable
defective.
Replacepower
supplyorpower
supplycable
Externalpower
sourcedefective.
Useotherexternal
powersource

Related product manuals