2-4
CDA3000 Operation Manual
2  Mechanical installation
2.4 Cold plate
 
 
Figure 2.2 Mounting clearances (see Table 2.3)
Step Action Comment
1
Mark out the positions of the tapped 
holes on the backing plate or the cooler. 
Cut a tap for each fixing screw in the 
backing plate. 
Dimensional drawings/hole 
spacing see Table 2.3.
The tapping area will provide 
you with good, full-area contact.
2
Clean the contact surface and coat it 
thinly and evenly with heat transfer 
compound.
The contact surface must be 
metallically bright. 
3
Mount the inverter module vertically on 
the backing plate or cooler. Tighten all 
screws to the same tightness.
Pay attention to the mounting 
clearances! Size of cooling 
surface see Table 2.4.
4
Mount the other components, such as the 
mains filter, line choke etc., on the 
backing plate.
Mains filter max. 20 cm below 
the inverter module
5
Continue with the electrical installation in 
section 3.
F
E
G
F
E1
UM-xxxx
CM-xxxx