EasyManua.ls Logo

Lust CDA32.006 - Fault Signals

Default Icon
74 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
A-2
CDA3000 Operation Manual
A.1 Current capacity
of inverter
modules
The maximum permissible inverter output current and the peak current
are dependent on the mains voltage, the motor cable length, the power
stage switching frequency and the ambient temperature. If the conditions
change, the maximum permissible current capacity of the inverter
modules also changes. Refer to the following graphs and tables.
(1) Continuous
(2) Intermittent* > 5 Hz rotating field frequency
Inverter modules 0.37 to 15 kW
I/I
N
= 1.8 (for 30 s at 4 kHz)
I/I
N
= 1.8 (for 30 s at 8 kHz)
I/I
N
= 1.8 (for 30 s at 16 kHz)
Inverter modules 22 to 90 kW
I/I
N
= 1.5 (for 60 s at 4 kHz)
I/I
N
= 1.5 (for 60 s at 8 kHz)
(3) Intermittent* 0 to 5 Hz rotating field frequency
Inverter modules 0.37 to 15 kW
I/I
N
= 1.8 (for 30 s at 4 kHz)
I/I
N
= 1.25-1.8 (for 30 s at 8 kHz)
Inverter modules 22 to 90 kW
I/I
N
= 1.5 (for 60 s at 4 kHz)
I/I
N
= 1-1.5 (for 60 s at 8 kHz)
*Intermittent I
N
> I
eff
(4) Pulse mode
Inverter modules 0.37 to 15 kW
I/I
N
= approx. 2.2 (at 4, 8, 16 kHz)
Inverter modules 22 to 90 kW
I/I
N
= approx. 1.8 (at 4, 8 kHz)
Inverter modules for 230 V systems
525404550
1
2
I
I
N
(1)
f [Hz]
(2)
(3)
(4)
I
eff
1
T
--
Σ
n
i1=
I
2
i
t
i
⋅⋅=
Inverter module
Rec. 4-pole
standard motor
[kW]
Switching
frequency of
power stage
[kHz]
Rated
current [A]
Peak current for
intermittent
mode
0 to 5 Hz [A]
Peak current for
intermittent
mode
> 5 Hz [A]
CDA32.004,Cx.x
1)
0.75
4
8
16
4
4
3
7.2
7.2
5.4
7.2
7.2
5.4
CDA32.006,Cx.x
1)
1.1
4
8
16
5.5
5.5
4.3
9.9
9.9
7.7
9.9
9.9
7.7
CDA32.008,Cx.x
1)
1.5
4
8
16
7.1
7.1
5.5
12.8
12.8
8
12.8
12.8
9.9
Peak current for 30 s with inverter module 0.75 to 15 kW
Peak current for 60 s with inverter module 22 to 90 kW
Cooling air temperature: 45 °C at power stage switching frequency 4 kHz
4 0 ° C a t p o w e r s t a g e s w i t c h i n g f r e q u e n c y 8 , 1 6 k H z
1) With heat sink HS3... or additional cooling surface
Mains voltage 1 x 230 V -20 % +15 %
Motor cable length 10 m
Mounting height 1000 m above MSL
End-to-end mounting

Other manuals for Lust CDA32.006