CDA3000 Operation Manual
3-5
3  Installation
DE
EN
FR
IT
ES
FR
1
2
3
4
5
A
Attention: If the inverter is operated as a controller with encoder (FOR 
motor control method), motor phases U,V and W must 
never be reversed! If the motor phases are reversed the 
inverter has no control over the motor. The motor may buck or 
accelerate in an uncontrolled manner (“race”).
Terminal box For proper EMC installation the motor terminal box must be HF-tight
(metal or metallized plastic). For cable introduction, packing glands with
large-area shield contact should be used. 
 
Motor temperature monitoring For thermal monitoring of the motor coil, a thermistor (PTC) may be
connected to terminals X3/ϑ- and ϑ+. The type used must be set during
commissioning in parameter 330-MOPTC (factory default setting is “off”). 
 
Attention: Contrary to DIN VDE 0660-303 (short circuit dedection 
<20Ω) the CDA3000 will note a short circuit at < 5 Ω.
(1) Thermistor (PTC)
(2)
Packing gland with shield 
contact
(3) Motor phases
(4) Grounding lead connection
Figure 3.4 Motor terminal box
1
2
U
VW
U
VW
(1)
(2)
(3)
(4)
Sensor
Tech. data
No PTC 
used
Standard
PTC
Linear
voltage evaluation
TSS,
thermostatic 
circuit-breaker
Usable type -
PTC to
DIN44082
KTY84-130, (tolerance 
band yellow)
Klixon
Parameter
330-MOPTC =
OFF DIN KTY TSS
Measurement 
voltage U
MAX
– 12 V –
Measuring range – 100 Ω to 15 kΩ –
Table 3.1 Motor temperature monitoring specification