CDA3000 Operation Manual
4-5
4  Commissioning
DE
EN
FR
IT
ES
FR
1
2
3
4
5
A
Note: If the connected IEC standard motor differs by more than two 
power classes from the rated power output of the inverter 
module, “D
RIVEMANAGER commissioning” with automatic 
motor identification should be carried out, see section 4.4. 
The same applies to commissioning of special motors such 
as reluctance, synchronous or HF motors. Please consult 
your project engineer.
   
 
Figure 4.3 Signal characteristic dependent on driving profile 
(ASTER=ROT_6)
Reference S2 (ISD03) S1(ISD02) ISA00
Analog reference at input ISA00 (R1) 0 0 active
Table frequency 601-FFTB1 (FS = 10Hz) 0 1 inactive
Table frequency 602-FFTB2 (FS = 15Hz) 1 0 inactive
Table frequency 603-FFTB3 (FS = 20Hz) 1 1 inactive
Table 4.1 Scaling of binary coded inputs ISD02 (S1) and ISD03 (S2)
Input signals
terminal assignment 2
(152-ASTER = ROT_6)
Output signals
terminal assignment 2
(152-ASTER = ROT_6)
H1 = Reference reached
H2 = Standstill
t [s]
   0
   0
   1
10 V
FMAX
  5 V
R1
  0 V
f [Hz]
STL
   0
   1
STR
   0
   1
S1
   0
   1
S2
FMAX
303-FMAX1
FFTB1
FFTB3
FFTB2
R1
R1
R1
R1
H1
H2