3.7.5 Terminal
assignment 3
Preset solution “Analog reference + correction, with rotary encoder”.
(1) Only encoder type HTL (24V supply) usable. The encoder is evaluated only in control
mode FOR. For notes on the rotary encoder see Figure 3.10.
Figure 3.9 Control terminal assignment, rotational drive with encoder
evaluation
Correction reference*: For a description of the function refer to the
CDA3000 Application Manual.
Features Parameter
Analog speed input for two
directions with speed correction
Encoder evaluation
152-ASTER = ROT_2
X2 Des. Function
20 OSD02
Relay contact
for “Ready”
message
19 OSD02
18 OSD02
17 DGND Digital ground
16 OSD01 “Reference reached” message
15 OSD00 “Standstill” message
14 DGND Digital ground
13
U
V
Auxiliary voltage 24 V
12 ISD03 Encoder track B
11 ISD02 Encoder track A
10 ISD01 Start/Stop anti-clockwise
9 ISD00 Start/Stop clockwise
8 ENPO Power stage hardware enable
7
U
V
Auxiliary voltage 24 V
6
U
V
5 OSA00 Actual frequency 0 ... FMAX
4 AGND Analog ground
3 ISA01 Correction reference* 0 V ... +10 V
2 ISA00 Reference 0 V ... + 10 V
1
U
R
Reference voltage 10.5 V, 5 mA
+24V
H1
H2
ENPO
STL
STR
N1
K0
-
+
0 ... 10 V
R1
R2
N2
B
A
+
-
M
3~
(1)
10 k
10 k
14
11
12

Other manuals for Lust CDA32.008