CDA3000 Operation Manual
4  Commissioning
4.6.2 Serial 
commissioning 
with  
D
RIVEMANAGER 
Precondition:
• All inverter modules are fully connected.
• The first drive is already fully commissioned into operation.
• A PC with installed DRIVEMANAGER user software (V3.0 or higher) is 
connected.
  
For more information refer to the DRIVEMANAGER Manual.
Step Action Comment
1
Connect your PC to the inverter 
module of the first drive and switch 
on the power to the inverter.
Use a standard serial cable (9-pin D-
SUB, socket/pin) e.g. LUST accessory 
CCD-SUB90x .
2
Start DRIVEMANAGER.
Automatically links to the connected 
inverter module.
If the connection fails, check the settings in the Tools > Options 
menu and try again by way of icon
.
3
Save the current data set 
with icon
, either in the 
parameter database 
(directory: c:/../userdata) of the 
D
RIVEMANAGER or on a floppy disk 
(a:/).
With icon the current data set of the 
connected device is always saved.
Give the file a name of your choice.
4a
Disconnect from all devices 
with icon 
4b
Connect your PC to the inverter module of the next drive and switch on the 
power to the inverter.
5
With icon  establish a link 
between the D
RIVEMANAGER 
and the newly connected 
device. 
6
With icon  load the data set 
saved in step 4 into the 
device.
The data set is stored in the device as 
user data set 1.
7
With icon  select the main 
window. 
Save the setting with 
button          ->
 
Repeat steps 4 ... 7 on each of the other drives.
Save data set from device to 
file
Download data set from file 
into device
Remember to save 
the setting.