Operation Manual
SMARTDRIVE VF1000 · Series M
Frequency inverter 1.1 to 4 kW
stop
return
start
enter
VAL
Hz
SMART
CARD
EN
ANTRIEBSTECHNIK
Question and Answer IconNeed help?

Do you have a question about the Lust SMARTDRIVE VF1408M and is the answer not in the manual?

Lust SMARTDRIVE VF1408M Specifications

General IconGeneral
TypeDC Drive
ModelVF1408M
ManufacturerLust
Rated Output Current8A
Cooling MethodForced Air Cooling
Enclosure RatingIP20
Control MethodVector Control
Communication InterfaceModbus
Protection FeaturesOvercurrent, Overvoltage

Summary

SMARTDRIVE VF1000 Series M Frequency inverter 1.1 to 4 kW

4 Operating the control unit KEYPAD KP100*

A.1 Safety instructions

A.2 Intended use

A.3 Design and accessories

A.5 VF1000M with CE - acceptance test

A.6 Instructions for correct EMC installation

1 Technical data

1.2 Data table

1.4 Device assembly

2 Electrical Connections

2.1 Connection plan

Detailed diagram showing all electrical connections for mains, motor, and control signals.

2.2 Fault transmission/interference immunity (EMC)

2.3 Power connections

Mains connection

Details how to connect the inverter to the mains power supply, including voltage requirements.

2.3.2 Motor connection

2.3.4 Motor temperature monitoring (PTC/PT1 design)

2.4 Control connections

2.4.2 Function of the FSINA reference input

2.4.3 Control functions with STR/STL

2.4.4 Control function via S1IND/S2IND/S3IND

2.4.5 MOP function with S1IND/S2IND

2.4.6 Signal outputs

Analog and Digital Output Functions

2.4.7 LUSTBus connection

2.4.8 INTERBUS-S connection (Design C8)

2.4.9 CAN-Bus connection (Design C2)

3 Operating and error diagnosis

3.3 Error messages

3.4 Motor/inverter-overload protection (I * t monitoring)

4.3.2 MOP function with KEYPAD KP100

5 Parameter list

6 Parameter description

Operating Mode and Reference Input

Defines operating modes and explains the selection of different reference input types.

6.3 Frequencies

Digital Input Frequency Selection and Ramps

6.6 Special functions

Automatic Load Control (I*R-Compensation)

Explains automatic load control for constant torque and reduced motor heating.

49-SC Slip compensation On/Off

Parameter Adjustments for Compensation and Control

Current Limit and Monitoring Parameters

61-SOUTA Analog/frequency output

95-ERR1 Error 1 [Decimal-0.1h]