2. SPECIFICATIONS
2-1 General Specification
Display 65 mm x 48 mm large LCD display
with bar graph indicator.
Measurement DCV, ACV, DCA, ACA, Resistance,
Capacitance, Frequency, Duty,
Diode, Continuity beeper.
A/D counts no. 4000 counts.
Range selection Auto range with manual range
selecting.
Special function Relative measurement, Data hold.
Data hold To freeze the display reading on the
LCD display.
Power On/Off Auto power of or manual power off.
management
@ Details please refer page 8
Relative To offset the measurement value.
measurement
Polarity Automatic Switching, " - " indicates
negative polarity.
Zero adjustment Automatic.
Sampling time Approx. 0.5 to 1 second.
Operating 0 to 50 (32 to 122 ),℃℉
Temp. & humidity Max. 80% RH.
Power supply 006 p dc 9V battery.
Power Approx. DC 1.7 mA.
consumption
2