SOUND LEVEL
METER
Model : SL-4010
Your purchase of this
SOUND LEVEL METE
R
marks a step forward for
you into the field of
precision measurement.
Althou
g
h this METER is a
complex and delicate
instrument, its durable
structure will allow many
years of use if proper
operatin
g
techniques are
developed. Please read
the followin
g
instructions
carefully and always keep
this manual within easy
reach.
OPERATION MANUAL
Question and Answer IconNeed help?

Do you have a question about the Lutron Electronics SL-4010 and is the answer not in the manual?

Lutron Electronics SL-4010 Specifications

General IconGeneral
BrandLutron Electronics
ModelSL-4010
CategoryMeasuring Instruments
LanguageEnglish

Summary

Product Features

Key Features Overview

Highlights include large LCD, 'A' frequency weighting, 'Fast' time weighting, built-in calibration VR, condenser microphone, data hold, and low battery indicator.

Technical Specifications

Display and Measurement Range

Details on the 3 1/2 digit LCD, measurement ranges (35-130 dB), resolution (0.1 dB), and frequency response (31.5 Hz-8,000 Hz).

Frequency Weighting Characteristics

Specifies 'A' frequency weighting network meeting IEC 61672 class 2, simulated as human ear response.

Time Weighting and Accuracy

Details 'Fast' time weighting and accuracy specifications for various frequencies under 94 dB input signal.

Calibration and Components

Information on the built-in calibration VR, microphone type, data hold function, and optional calibrator.

Operating Conditions and Power

Specifies operating temperature (0-50°C), humidity (<80% RH), power supply (9V DC), and consumption (approx. 6 mA).

Physical Dimensions and Accessories

Provides unit dimensions (250x70x28mm), weight (250g), and lists standard and optional accessories.

Front Panel Description

Microphone and Display Identification

Identifies the electric condenser microphone and the digital display unit on the front panel.

Control Switches and Indicators

Locates range switch, calibration VR, power/hold switch, and range indicators on the front panel.

Battery Compartment Location

Indicates the position of the battery compartment and cover on the front panel.

Operational Procedures

Measuring Procedure Steps

Guides on powering on, selecting the measuring range, taking readings, and using the data hold function.

Battery Replacement Guide

Instructions for replacing the battery when the low battery indicator appears.

Calibration Process

Calibrator Preparation and Setup

Details on preparing an optional sound calibrator and connecting it to the sound level meter.

Setting Range and Adjusting VR

Instructions to set the range switch and adjust the external calibration VR for accurate readings.

Frequency Weighting Network Characteristics

A-Weighting Performance Data

Presents a table of A-weighting characteristics and tolerances for various frequencies (31.5 Hz to 8 KHz).