LXP HYBRID INVERTER
USER MANUAL
Version:EN-UM-2.0-04
LXP 3K/3.6K/4K/4.6K/5K/6K Hybrid
LXP 4K/5K/6K HB
LXP 3K/3.6K/4K/4.6K/5K/6K MG
Monitor APP Download
Android
IOS
Standard Model:
Parallel Model:
High Voltage Model:

Questions and Answers

  • D
    Deborah BrowningSep 23, 2025
    How to fix 'Internal fault' error on Lux Power Technology Inverter?
    • L
      llawrenceSep 23, 2025
      If your Lux Power Technology Inverter displays the error 'E026 Internal fault', check the parallel CAN cables between inverters and ensure the balance resistor is in the correct position.
  • J
    Joshua TaylorAug 25, 2025
    Why is my Lux Power Technology LXP 3K Hybrid showing 'AC voltage out of range'?
    • R
      Richard GuzmanAug 25, 2025
      If your Lux Power Technology Inverter shows the 'W017 AC voltage out of range' error, you should check the AC grid voltage to ensure it is within the acceptable range.
  • C
    Casey KeithAug 25, 2025
    What causes 'AC frequency out of range' on a Lux Power Technology LXP 3K Hybrid Inverter?
    • P
      Peter RamirezAug 26, 2025
      If you see the 'W018 AC frequency out of range' error on your Lux Power Technology Inverter, check the AC grid frequency to ensure it is within the correct range.
  • J
    Jessica AndersonAug 27, 2025
    How to fix 'PV short circuit' error on Lux Power Technology LXP 3K Hybrid Inverter?
    • J
      Julie JacksonAug 27, 2025
      If your Lux Power Technology Inverter is showing a 'W023 PV short circuit' error, you should check and fix the PV input connection.
  • J
    Jaime JordanAug 27, 2025
    What to do if Lux Power Technology LXP 3K Hybrid shows 'Battery voltage high'?
    • D
      Dr. Alfred JohnsonAug 27, 2025
      If your Lux Power Technology Inverter displays the error 'W025 Battery voltage high', you should check and fix the battery connection.
  • M
    Monique BrightSep 13, 2025
    What to do if Lux Power Technology LXP 3K Hybrid shows 'UPS power reversed'?
    • V
      Vincent JonesSep 14, 2025
      If your Lux Power Technology Inverter displays the error 'E013 UPS power reversed', restart the inverter. If the error persists, further assistance may be needed.
  • S
    Steven AcevedoSep 12, 2025
    What to do if Lux Power Technology LXP 3K Hybrid Inverter shows 'PV isolation low'?
    • H
      Howard HurleySep 12, 2025
      If your Lux Power Technology Inverter displays the error 'W020 PV isolation low', restart the inverter. If the error persists, further assistance may be needed.
  • S
    Steven NelsonSep 12, 2025
    What to do if Lux Power Technology Inverter shows 'Leakage current high'?
    • J
      James WardSep 12, 2025
      If your Lux Power Technology Inverter displays the error 'W021 Leakage current high', restart the inverter. If the error persists, further assistance may be needed.
  • F
    floydjonathanSep 4, 2025
    Why is my Lux Power Technology LXP 3K Hybrid showing 'PV voltage high'?
    • Q
      qstephensSep 4, 2025
      If your Lux Power Technology Inverter displays the error 'E021 PV voltage high', check the PV input connection.
  • N
    Natalie AllenSep 2, 2025
    What should I do if my Lux Power Technology LXP 3K Hybrid shows 'Parallel AC inconsistent'?
    • A
      Albert LawsonSep 2, 2025
      If your Lux Power Technology Inverter displays the 'E011 Parallel AC inconsistent' error, check the AC connection.

Lux Power Technology LXP 3K Hybrid Specifications

General IconGeneral
ModelLXP 3K Hybrid
Rated Power3kW
Max. DC Input Voltage550 V
Output Voltage230Vac
Frequency50/60 Hz
Battery Voltage48 V
Max Solar Input Voltage550 V
Efficiency97.6%
Operating Temperature-25°C to +60°C
Battery TypeLithium-ion
CommunicationRS485
ProtectionShort circuit protection

Related product manuals