If the grill is installed by a professional installer or technician, be sure that they show you where
your gas supply shut-off is located. All gas lines must have a shut-off that is readily and easily
accessible. If you smell gas, check for gas leaks immediately. Check only with a soap and water
solution.. NEVER CHECK FOR GAS LEAKS WITH AN OPEN FLAME.
Keep any electrical supply cord away from any heated surface. Electrical cords should be placed
away from walkways to avoid tripping hazard.
Do not use this unit until a leak check has been performed.
Do not move grill while hot or in use.
Do not operate this unit under the influence of drugs, heavy medication, or alcohol.
Do not lean on shelves or place more than 25 pounds on a side shelf.
If any burner does not light or goes out during operation, turn off all gas control knobs with hood
open and wait (5) minutes before attempting to re-light.
HOW TO PERFORM A LEAK TEST:
A) Create a soapy solution of half water and half dishwashing detergent.
B) Make sure that all control knobs are in the off position.
C) Turn on fuel supply. Turn cylinder valve knob counter clockwise (right to left) one rotation.
D) Apply soap solution generously by paint brush or squirt bottle on all connections and fittings.
E) If you see any “growing” bubbles on any of the connection points, you have detected a
gas leak. IMMEDIATELY turn off the gas from the main gas source.
E) Check the hose for signs of cracks abrasion and leaks.
F) A leak may be stopped by tightening the loose joint, or by replacing the faulty part with a
replacement part recommended by the manufacturer.
E) Do not attempt to repair the cylinder valve if it should become damaged,THE CYLINDER MUST
BE REPLACED.
DANGER: TO PREVENT EXPLOSION OR FIRE HAZARD:
DO NOT use or permit sources of ignition including smoking in the area while doing a leak test
Perform leak tests outdoors only. Never use flame or fire to do a leak test.
NOTE: NEVER USE GRILL WITHOUT LEAK TESTING.