SECTION 5 LYCOMING OPERATOR’S MANUAL
MAINTENANCE PROCEDURES O-360 AND ASSOCIATED MODELS
Figure 5-5. Exhaust Bypass Valve Open and Closed Setting
Figure 5-6. Timing Marks on Rotating Magnet
5-12

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Lycoming IO-360 Series and is the answer not in the manual?

Lycoming IO-360 Series Specifications

General IconGeneral
Oil SystemWet Sump
Engine TypeHorizontally Opposed, 4-Cylinder, Air Cooled
Displacement361 cubic inches (5.9 liters)
Bore5.125 in (130.2 mm)
Stroke4.375 inches (111.1 mm)
Cooling SystemAir Cooled