EasyManua.ls Logo

M3S Triton - The ADV; Cell Calibration and Ppo Display Set-Up

Default Icon
40 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
orifice).
You can check the flow with a Stopwatch :
Gas line connected to the O
2
tank
open the tank
on the SPG, level has to be upper than 150b
close the tank
Time the pressure decrease from 150b to 100b
You can estimate M3S valve flow thanks to this graph.
Figure 3.5 Time graph from 150b to 100b
3.3.3 the ADV
The Triton’s ADV is adjustable. The adjustment of diluent can be done accurately thanks to
the spanner adjuster. The intermediate pressure of the diluent regulator must be setted up
to 8 to 8.5b for optimum performances of the ADV.
WARNING The couple Inflator hose / ADV connector have to be check before diving. Make
sure ADV gives you diluent propely when fired.
3.3.4 Cell calibration and PpO
2
display set-up
While using a rebreather, it is not enough to get only a quantitative information on the gas
but it is also necessary to get a qualitative information in real time about the gases which
are contained inside the loop.
It is necessary to dive only with correctly calibrated cells in order to be sure to have a correct
information during the dive.
28