EasyManua.ls Logo

mabe MMI09CDBWCCCHI8 - piping and cable connections

mabe MMI09CDBWCCCHI8
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
84
Thermal Insulation
Wrapped with vinyl tape
Large pipe
Small
pipe
Power
cord
Drain hose
(prepared by user)
Thermal
insulation
tube
Piping direction
1
3
2
4
Cut here
Unloading
piece
Cut unloading piece
along de line.
Note: When installing pipe in
direction 1, 2 or 4, cut off the
corresponding unloading piece
from the indoor unit base.
3. Indoor unit piping installation
Route the piping (liquid and gas) as well as cables through the
wall hole from outside or put them through from inside after in-
door piping and cables connection is complete to connect to the
outdoor unit.
Select whether to remove the unloading piece of
f according to
the piping direction (as shown below).
After connecting the piping, install the drain hose. Then connect
the power cords. After completing the connections, wrap the
piping, cords and drain hose together with thermal insulation
materials.
Thermal insulation of piping joints. Wrap the piping joints with
thermal insulation materials and then wrap with a vinyl tape.
Thermal insulation of piping.
a. Place the drain hose under the
piping.
b. Insulation material uses poly-
ethylene foam over 6 mm in thick-
ness.
Note: Drain hose is prepared by
user.

Related product manuals