15 Configuration and Operation
© 2020 MacroAir Technologies Toll Free: 866 668 3247 Fax: 909 890 2313 www.macroairfans.com
Controller 4 Operation Manual 90-30027-00 Rev A-01 Date: 032720
Controller 4 Screen Setup
The touchscreen may require additional setup before operating the fans. Please refer to the
steps below to properly configure your controller.
1. Power on the fans. The screen will illuminate as soon as power is supplied.
2. The screen will search for fans and take you to the home screen once the scan is
complete.
3. AVD 370 and Y series fans do not require further setup. If you only have these fans on the
network, set a speed and direction using the buttons on the home screen. Y series fans
will operate normally. AVD 370 fans will spin in reverse at a preset speed, automatically
determine the blade length and resume operation at the speed and direction command.
4. AVD3, 550, 780, and X series fans REQUIRE the blade size to be programmed in order to
function correctly. The blade size is set via the “Fan Diameter” screen. Once the size is
programmed into every AVD3, 550, 780, and X series fan on the network, the fans can be
operated normally.