(6) LEARN
This submenu is for coin self-learning parameter tests and
adjustments. It is not available for users.
9. Trouble Shooting
During self-testing or machine working status, sometimes the LCD
screen may display following error code:
1ERROR ADJUST
CHECK THE SENSOR 0
ERROR:
ADJUST
·When it displays ERROR ADJUST, it means the signal of alloy sensor is
abnormal, the self-test can not be done normally, please contact your
local distributor for solution.
2ERROR 01
CHECK THE SENSOR 1
ERROR:
01
·When it displays ERROR 01, it means the IR transistor is blocked,
please check the IR transistor and also the connecting cable. After the
problem is solved, please press CLR key to enter into main interface.
If the problem can not be solved, please contact your local distributor
for solution
3ERROR 02
CHECK THE SENSOR 2
ERROR:
02
·When it displays such error message, it means there is foreign thing