Name
Vacuum 20
Enter the correct value using UP-DOWN buttons. Confirm by pressing ENTER. Display will
show the entered data.
Refrigerant qty g: 700
Vacuum: 20
Select ENTER to save the data. You will return to the user’s vehicles selection list.
8.3 Automatic program (with a memory card),
When entering the program selection mode (see 9 PROGRAMS) the following menu
appears:
Auto Progr. ■
User progr. □
Select using UP-DOWN buttons.
Confirm by pressing ENTER.
Specify refrigerant weight ■
User vehicles □
Select using UP-DOWN buttons.
Confirm by pressing ENTER.
Specify refrigerant weight
Refrig. g XXXX
Specify the correct refrigerant weight using UP-DOWN buttons.
Confirm by pressing ENTER.
Refrigerant qty g: XXXXX
Vacuum: XX:XX
Vacuum generation time is calculated based on the refrigerant quantity specified.
Use UP-DOWN buttons to select the oil/UV injection program.
See 9.5 Programming oil/UV injection phase.
Confirm by pressing ENTER to start the automatic program with manual oil/UV injection.
8.3.1 Searching the vehicle model (Database)
Choose select model function to use the database.
Specify refrigerant weight ■
Select model □
Select using UP-DOWN buttons.
Confirm by pressing ENTER.
User vehicles