INSTRUCTION MANUAL FOR DISHWASHERS
Page 14 of 16
The following settings should only be configured by a qualified technician.
The parameters listed below can be set during installation of afterwards, accessing the settings menu as
follows:
Machine in standby with door open.
Press buttons 1 and 2 together (ON/OFF and SPECIAL PROGRAMME SELECTION) for 5 seconds
and enter the key KEY 12 (buttons 3 and 4 to change the parameter, 1 to confirm).
Then press button 1 (ON/OFF) repeatedly to scroll through the following headings, enabling and/or
changing them using buttons 3 and 4 (the modified parameter is memorised without being confirmed).
The list of parameters may vary according to the type of dishwasher.
Boiler temperature settings for programmes. In the versions with
atmospheric boiler (rinse pump) there are different settings for each
programme (b1 – b2 – b3)
Tub temperature regulation for programmes. Rinse pump versions have
different settings for each programme (t1 – t2 – t3)
Enabling the Thermostop function, which guarantees the correct
rinse temperature.
Enabling the Energy Saving function, which guarantees
energy savings when the dishwasher is on but not in use.
Manual operation of detergent doser
Manual operation of rinse aid doser
Water supply hardness setting, for machines with built-in water softener, set
according to measured water hardness.
Cycle counter setting and activation to enable the Service alert for an
external water softener.
The Service alert can be cancelled by holding pressed all 4 buttons with the
machine off and the door open.
Manual operation of the rinse pump
Manual operation of the drain pump
Automatic enabling of automatic starting
Once all necessary parameters have been set, to exit and save any changes simply press and hold
button 1 for a few seconds until the display switches off.