8
(Auto-ranging)
99.99mF
±(5% + 5 digits)
0.01mF
7
9.999µF
0.001µF
99.99µF
±(3.0% + 5 digits)
0.01µF
Range
99.99nF*
999.9nF
Accuracy ±(% of reading+digits)
±(4.5% + 20 digits)
Function
Capacitance
Frequency with test leads (AC Voltage)
* < 99.99nF (no specification)
Input Protection: 300V DC or 300V AC RMS.
Resolution
0.01nF
0.1nF
999.9µF
0.1µF
9.999mF
0.001mF
Range
10Hz to 100kHz
Accuracy ±(% of reading+digits)
±(1.0% + 5 digits)
Function
Frequency
Input Protection: 1000V AC RMS
Sensitivity: > 15V AC RMS
Frequency (AC Current)
(Auto-ranging)
Range
45Hz to 1kHz
Accuracy ±(% of reading+digits)
±(1.0% + 5 digits)
Function
Frequency
Sensitivity: > 20A
(Auto-ranging)
Range
20.0% to 80.0%
Accuracy ±(% of reading+digits)
±(1.2% + 10 digits)
Function
Duty Cycle
Resolution
0.1
Input Protection: 300V DC or 300V AC RMS.
Sensor: Type K Thermocouple
7
Range
-20.0 to 1000°C
-4.0 to 1832°F
Accuracy ±(% of reading+digits)
±(3% + 3°C)
Function
Temperature
Resolution
0.1/1°C
0.1/1°F
(Type-K)
±(3% + 5°F)
7
Input Protection: 300V DC or 300V AC RMS.
7
Testing Condition
Forward DCA is approx .1mA,
open circuit voltage MAX 3V
Reading
Forward voltage drop of Diode
Function
Diode
Test current MAX 1.5mA
While resistance is less than (50Ω)
Buzzer makes a long sound,
Continuity