40.00kΩ ±(1.5% + 2 digits)
10Ω
400.0kΩ ±(1.5% + 2 digits)
100Ω
Range
400.0Ω
4.000kΩ
Accuracy ±(% of reading+digits)
±(1% + 4 digits)
±(1.5% + 2 digits)
Function
Resistance
Input Protection: 300V DC or 300V AC RMS
Resolution
0.1Ω
1Ω
4.000MΩ ±(2.0% + 5 digits)
1kΩ
40.00MΩ ±(3.0% + 8 digits)
10kΩ
7
5. Specifications
Range
40.00A
400.0A
Accuracy ±(% of reading+digits)
±(2.0% + 8 digits)
±(2.5% + 8 digits)
Function
AC True RMS Current
Inrush current Maximum Input: 400A Inrush current Sensitivity: >2A.
Over range protection: Maximum input 400A.
Accuracy specified from 5% to 100% of the measuring range.
Frequency Response: 50Hz to 60Hz True RMS.
Resolution
10mA
100mA
400.0V ±(1.0% + 3 digits)
100mV
1000V ±(1.2% + 3 digits)
1V
Range
4.000V
40.00V
Accuracy ±(% of reading+digits)
±(1.0% + 3 digits)
±(1.0% + 3 digits)
Function
DC Voltage
Maximum input: 1000V DC
Resolution
1mV
10mV
400.0V ±(1.2% + 5 digits)
100mV
1000V ±(1.5% + 5 digits)
1V
Range
4.000V
40.00V
Accuracy ±(% of reading+digits)
±(1.2% + 5 digits)
±(1.2% + 5 digits)
Function
AC True RMS Voltage
AC voltage bandwidth: 50 to 1000Hz (sine) 50/60 (all wave)
Variable frequency Drive TEST AC voltage range: 100V---600V.
Accuracy specified from 5% to 100% of the measuring range
Maximum Input: 1000V AC RMS.
PEAK Maximum Input: 1000V
Resolution
1mV
10mV
(with VFD)