Resistance Measurement
1. Insert the black test lead into the negative COM
terminal and the red test lead into
the positive V/ terminal.
2. Set the function switch to the
position.
3. Use SELECT Button to select
4. Touch the test probe tips across
the circuit or component under
test. It is best to disconnect one
side of the device under test so the
rest of the circuit will not interfere
with the resistance reading.
5. For Resistance tests, read the resistance on the LCD
display.
Capacitance Measurement
WARNING: To avoid electric shock, discharge the capacitor
under test before measuring.
1. Insert the black test lead into the
negative COM terminal and the
red test lead into the positive V/
terminal.
2. Set the function switch to the
position.
3. Use SELECT Button to select nF
4. Touch the test probe tips across the circuit or
component under test. It is best to disconnect one
side of the device under test so the rest of the circuit
will not interfere with the resistance reading.
5. Capacitance value displayed on the LCD display.