State of abnormality Probable cause (malfunction) Remedy
Thewirelessactivationlampdoes
notlight/blink.
Thewirelessunitisnotinstalledintothetool.
Thewirelessunitisimproperlyinstalled
into the tool.
Install the wireless unit correctly.
Theterminalofthewirelessunitand/or
the slot is dirty.
Gentlywipeoffdustanddirtontheterminalofthe
wireless unit and clean the slot.
Thewirelessactivationbuttononthe
tool has not been pushed.
Push the wireless activation button on the tool
briey.
Thestand-byswitchonthevacuum
cleanerisnotsetto"AUTO".
Set the stand-by switch on the vacuum cleaner to
"AUTO".
No power supply
Supply the power to the tool and the vacuum cleaner.
Cannotnishtoolregistration/can-
cellingtoolregistrationsuccessfully.
Thewirelessunitisnotinstalledintothetool.
Thewirelessunitisimproperlyinstalled
into the tool.
Install the wireless unit correctly.
Theterminalofthewirelessunitand/or
the slot is dirty.
Gentlywipeoffdustanddirtontheterminalofthe
wireless unit and clean the slot.
Thestand-byswitchonthevacuum
cleanerisnotsetto"AUTO".
Set the stand-by switch on the vacuum cleaner to
"AUTO".
No power supply
Supply the power to the tool and the vacuum cleaner.
Incorrect operation
Pushthewirelessactivationbuttonbrieyandperform
thetoolregistration/cancellationproceduresagain.
Thetoolandvacuumcleanerisaway
fromeachother(outofthetransmission
range).
Get the tool and vacuum cleaner closer to each
other.Themaximumtransmissiondistanceis
approximately 10 m however it may vary according
to the circumstances.
Beforenishingthetoolregistration/
cancellation;
- the switch trigger on the tool is pulled or;
- the power button on the vacuum
cleaner is turned on.
Pushthewirelessactivationbuttonbrieyand
performthetoolregistration/cancellationprocedures
again.
Thetoolregistrationproceduresforthe
toolorvacuumcleanerhasnotnished.
Performthetoolregistrationproceduresforboththe
tool and the vacuum cleaner at the same timing.
Radio disturbance by other appliances
which generate high-intensity radio waves.
Keepthetoolandvacuumcleanerawayfromtheappli-
ances such as Wi-Fi devices and microwave ovens.
Thevacuumcleanerdoesnotrun
alongwiththeswitchoperationof
the tool.
Thewirelessunitisnotinstalledintothetool.
Thewirelessunitisimproperlyinstalled
into the tool.
Install the wireless unit correctly.
Theterminalofthewirelessunitand/or
the slot is dirty.
Gentlywipeoffdustanddirtontheterminalofthe
wireless unit and clean the slot.
Thewirelessactivationbuttononthe
tool has not been pushed.
Pushthewirelessactivationbuttonbrieyandmake
sure that the wireless activation lamp is blinking in blue.
Thestand-byswitchonthevacuum
cleanerisnotsetto"AUTO".
Set the stand-by switch on the vacuum cleaner to
"AUTO".
More than 10 tools are registered to the
vacuum cleaner.
Performthetoolregistrationagain.
Ifmorethan10toolsareregisteredtothevacuum
cleaner, the tool registered earliest will be cancelled
automatically.
Thevacuumcleanererasedalltool
registrations.
Performthetoolregistrationagain.
No power supply Supply the power to the tool and the vacuum
cleaner.
Thetoolandvacuumcleanerisaway
fromeachother(outofthetransmission
range).
Getthetoolandvacuumcleanerclosereachother.The
maximum transmission distance is approximately 10 m
however it may vary according to the circumstances.
Radio disturbance by other appliances
which generate high-intensity radio waves.
Keepthetoolandvacuumcleanerawayfromtheappli-
ances such as Wi-Fi devices and microwave ovens.
Thevacuumcleanerrunswhilethe
tool'sswitchtriggerisnotpulled.
Other users are using the wireless activa-
tionofthevacuumcleanerwiththeirtools.
Turnoffthewirelessactivationbuttonoftheother