Maintenance and care
112
If it is necessary to fill the expansion tank when the engine is hot, the following should be noted:
D In order to be able to operate the hot engine
again without an alarm, after opening the lock
ing cap, there must be an admission pressure
of 0.7 bar in the cooling system.
D In order to achieve this a pressure valve (1) is
fitted on the expansion tank, to which a propri
etary air pump can be connected. This can be
used to pump the system pressure up to
0.7 bar