M&R Companies 440 Medinah Rd. Roselle, IL 60172 USA 21
Tel: +630-858-6101 Fax: +630-858-6134 www.mrprint.com | store.mrprint.com
6.1 Starlight CTS Conversion
Converting a Version 2 Starlight unit to CTS compatibility.
Note: With the glass removed your exposure times are quicker, so testing is necessary to find the
optimum exposure times.
Note: Version 2 units have internally mounted Fans (1).
1. Power Off (2) the Starlight and disconnect the main incoming power source (3).
2. Using a Phillips screwdriver, remove the two front corner glass Hold Down Brackets (4). Carefully
remove Glass.
Note: Wear Safety Glasses when working with glass.