2-60
To extend and retract the telescope (set the lever to II).
- Press button 3 (Fig. C) to power the distributor and, at the same time, pull the lever (Fig.
E) to:
• A - to retract the telescope
• B - to extend the telescope
To raise and lower the upper arm (set the lever to III).
- Press button 3 (Fig. C) to power the distributor and, at the same time, push the lever
(Fig. F) to:
• A - to lower the upper arm
• B - to raise the upper arm
Rescue procedure on the main distributor:
For turret right rotation (set the lever to IV).
- Turn the wheel on valve 4 (Fig. H) clockwise.
- Press button 3 (Fig. C) to power the distributor and, at the same time, pull the lever
(Fig. G) to B.
- Turn the wheel on valve 4 (Fig. H) anti-clockwise.
For turret left rotation (set the lever to IV).
- Turn the wheel on valve 5 (Fig. H) clockwise.
- Press button 3 (Fig. C) to power the distributor and, at the same time, pull the lever
(Fig. G) to B.
- Turn the wheel on valve 5 (Fig. H) anti-clockwise.
To raise the pendular arm (set the lever to IV).
- Turn the wheel on valve 6 (Fig. H) clockwise
- Press button 3 (Fig. C) to power the distributor and, at the same time, pull the lever
(Fig. G) to B.
- Turn the wheel on valve 6 (Fig. H) anti-clockwise.
To lower the pendular arm (set the lever to IV).
- Turn the wheel on valve 7 (Fig. H) clockwise
- Press button 3 (Fig. C) to power the distributor and, at the same time, pull the lever
(Fig. G) to B.
- Turn the wheel on valve 7 (Fig. H) anti-clockwise.
G
F
E
H
II
III
IV
A
B
A
B
B
4
6
5
7
647414 EN (27/05/2015)