3-27
C18 OVERLOAD
CHECK
- The overload must activate at between 1.1 and 1.2 times the nominal load (see CHAPTER 2 - General characteristics).
Expected result:
• Nominal load 230 Kg: activation load between 253 kg and 276 kg
- The overload sensors must activate at the same time.
Refer to the repair manual for information about adjusting the overload
C19 STOPPING DISTANCE
CHECK
STOPPING DISTANCE ON HORIZONTAL GROUND:
- The stopping distance is tested on flat ground with 1.1 times the nominal load in the basket.
- Reach maximum speed and then release the control.
Expected result:
On horizontal ground
Stopping distance
Transport speed 1400 + or - 300
Working speed 160 + or - 50
CHECK BRAKE HOLDING ON A SLOPE
- Place the nacelle on a nominal 25% slope static with 1.1 times the nominal load in the basket.
Expected result: no slipping of the nacelle must be detected after one minute.
647414 EN (27/05/2015)