JIB - BASKET
32
547379EN
55 (08/03/2017)
55.2.3 REMOVAL OF PADS OF TELESCOPE MOVING TUBE
- Remove the telescopic cylinder (6TELESCOPIC CYLINDER REMOVAL,
5 63).
- Remove the exible guide fasteners on the moving tube (1, 055 8).
- Sling the basket/jib/hinge assembly (2, 055 8):
3 without steering actuator (3D - JIB) 230 kg (507 lbs)
3 with steering actuator (3D - JIB) 267 kg (589 lbs)
- Remove the axles (3, 055 8) then remove the basket/jib/hinge
assembly nearby to avoid damaging the hydraulic hoses and
wiring harnesses.
- Release the pads of the telescope jib by gently releasing the
moving tube (1, 055 9).
- Remove the pads (2, 055 9) of the telescope jib, pay attention to
the position and number of adjustment plates.
- Remove the moving tube by allowing it to slide towards the rear:
3 120 AETJL : 102 kg (225 lbs)
3 150 AETJC et 150 AETJL - 150 AETJC 3D - AETJ43 - AETJ43 3D:
116 kg (256 lbs)
3 170 AETJL - AETJ49 : 148 kg (326 lbs)
- Remove the pads (1, 055 10), pay attention to the position and
number of adjustment plates.
- Get new pads (see parts catalog).
- Fit the pads and adjustment plates, then check the clearance
(655.1.1 CHECK THE CLEARANCE OF THE TELESCOPE, 5 31).
55 - 8
1
1
3
3
2
55 - 9
2
2
1
55 - 10
1
1
1