Part Number 000015432 Rev02 5/21 107
Cycle Times/24-Hour Ice Production/
Refrigerant Pressure Charts
These charts are used as guidelines to verify correct ice
machine operation.
Accurate collection of data is essential to obtain the
correct diagnosis.
Refer to “Refrigeration System Diagnostics” for the
data that must be collected. This list includes: before
beginning service, ice production check, installation/
visual inspection, water system checklist, safeguards,
discharge and suction pressure analysis.
Ice production checks that are within 10% of the chart
are considered normal. This is due to variances in
water and air temperature. Actual temperatures will
seldom match the chart exactly.
Zero out manifold gauge set before obtaining pressure
readings to avoid misdiagnosis.
Discharge and suction pressure are highest at the
beginning of the cycle. Allow system to stabilize, then
verify the pressures are within the range indicated.
Water temperature will affect suction and discharge
pressure - 50° water temperature will result in
pressures on the lower end of the ranges specified.
90° water temperatures will result in pressures on the
upper end of the ranges specified.