38 Part Number 000015432 Rev02 5/21
Component Disassembly for Descaling and
Sanitizing
n
Warning
Disconnect electric power to the ice machine at the
electric switch box before proceeding.
n
Warning
Wear rubber gloves and safety goggles (and/or face
shield) when handling Ice Machine Cleaner or Sanitizer.
,
Caution
Do not mix Cleaner/Descaler and Sanitizer solutions
together. It is a violation of Federal law to use these
solutions in a manner inconsistent with their labeling.
GENERAL INFORMATION
The ice machine must be disassembled, descaled and
sanitized every six months.
1. Turn off the water supply to the ice machine at the
water service valve, or disconnect water supply line
at float valve quick disconnect by depressing stainless
steel lever.
2. Remove the components you want to descale or
sanitize. See the pages specific to the model you are
working on for removal procedures.
3. Soak the removed parts to descale and sanitize.
Solution Type Water Mixed With
Cleaner/Descaler 1 gal. (4 L)
16 oz. (500 ml)
cleaner/descaler
Sanitizer 6 gal. (23 L) 4 oz. (120 ml) sanitizer