Remedial Cleaning Procedure
Ice machine cleaner/descaler is used to remove lime scale
or other mineral deposits. It is not used to remove algae or
slime. Refer to “Sanitizing Procedure” for removal of algae
and slime. To initiate a descaling cycle using Manitowoc’s
Cleaning Technology use the following procedure.
Step 1 To start a cycle, move the toggle switch to the
CLEAN position. Water will flow through the water dump
valve and down the drain.
Step 2 Remove the top panel and translucent plastic
ice chute cover. Wait about one minute then add the
proper amount of Manitowoc Ice Machine Cleaner/
Descaler. Rinse the descaler from the top of the evaporator
with 2 ounces (60 ml) of clear water and re-install cover
,
Caution
Use only Manitowoc approved Ice Machine Cleaner/
Descaler part number 000000084. It is a violation
of Federal law to use these solutions in a manner
inconsistent with their labeling. Read and understand
all labels printed on bottles before use.
Model Amount of Cleaner/Descaler
Part Number 000000084
CNF0201 CNF0202 2 ounces (60 ml)