70 Part Number 000015432 Rev02 5/21
Example:
1. Collected ice for 7 minutes 12 seconds.
2. Total weight (minus container) = 1.25 lbs.
3. 1.25 lbs. x 200 = 250 lbs. of ice every 24 hours.
4. Compare the capacity to the 24-hour ice production
chart for the model being tested.
5. Ice production checks that are within 10% of the
charted capacity are considered normal due to
variances in air and water temperatures. Actual
temperatures will seldom match the chart exactly.