134 Part Number STH038 5/12
7. Press the Checkmark again. A submenu with
Export ALL and Export Setup appears.
NOTE:
There are four files stored in ice machine memory:
Asset Data - ASDATAoo.CSV
Operating Data - OPDATAoo.CSV
Real Time Data - RTDATAoo.CSV
Ice Machine Settings - Settinoo.CSV
Select only “Ice Machine Settings” file when multiple
machines will be programmed with the same user
specified settings. Select “Export All” if you are
installing a replacement board.
8. Highlight Export ALL or Export Setup, depending
on your requirements, and press the Checkmark.
A display of instructions will appear.
9. Follow these on-screen instructions to:
A. Insert Drive (Insert the flash drive into the
USB port on the ice machines control board.)
B. Press Check (Press the Checkmark.)
C. Wait For Comp (Wait approximately 5 to 10
minutes for the download to complete.
D. Depending on software version either Export
Complete, Success or the On/Off screen will
appear.