Part Number 040005626 5/17 119
M0500A SELF-CONTAINED AIR-COOLED
NOTE: These characteristics may vary depending on
operating conditions.
Cycle Times
Freeze Time + Harvest Time = Total Cycle Time
Times in minutes
24 Hour Ice Production
Based on average ice slab weight of 4.6 - 5.2 lb (2087 - 2359 g).
Operating Pressures
Suction pressure drops gradually throughout the freeze cycle
Air Temp.
Entering
Condenser
°F/°C
Freeze Time
Harvest
Time
Water Temperature °F/°C
50/10 70/21 90/32
70/21 11.9-13.6 14.1-16.1 15.7-17.9
1.0-2.5
80/27 13.6-15.5 15.1-17.2 16.6-19.0
90/32 14.9-17.0 15.5-17.7 17.7-20.2
100/38 16.6-19.0 18.3-20.9 20.2-23.1
110/43 18.9-21.5 19.5-22.3 20.6-23.5
Air Temp.
Entering
Condenser
°F/°C
Water Temperature °F/°C
50/10 70/21 90/32
70/21 495 425 385
80/27 440 400 365
90/32 405 390 345
100/38 365 335 305
110/43 325 315 300
Air Temp.
Entering
Condenser
°F/°C
Freeze Cycle Harvest Cycle
Discharge
Pressure
PSIG
Suction
Pressure
PSIG
Discharge
Pressure
PSIG
Suction
Pressure
PSIG
50/10 260-325 60-36 140-175 100-120
70/21 270-340 65-37 150-185 105-130
80/27 275-380 65-37 165-200 110-150
90/32 340-400 75-38 190-220 130-160
100/38 380-500 80-42 280-320 180-235
110/43 440-520 80-44 290-330 185-240