Removal from Service/Winterization
AIR-COOLED MODELS
1. Clean and sanitize the ice machine.
2. Place the toggle switch in the off position to turn
off the ice machine.
3. Turn off the water supply, disconnect and drain
the incoming ice-making water line at the rear of
the ice machine and drain the water trough.
4. Energize the ice machine, wait one minute for the
water inlet valve to open and blow compressed air
in both the incoming water and the drain openings
in the rear of the ice machine to remove all water.
5. Place the toggle switch in the off position and
disconnect the electric power at the circuit
breaker or the electric service switch.
6. Fill spray bottle with sanitizer and spray all interior
food zone surfaces. Do not rinse and allow to air
dry.
7. Replace all panels.
WATER-COOLED MODELS
1. Perform steps 1-6 under “ Air-Cooled Models.”
2. Disconnect the incoming water and drain line from
the water-cooled condenser.
3. Energize the ice machine in the freeze cycle. The
increasing refrigerant pressure will open the water
regulating valve.
4. Blow compressed air through the condenser until
no water remains.