Part Number 040005626 5/17 125
M1400A SELF-CONTAINED AIR-COOLED
Preliminary Data, Subject to Change
Characteristics vary depending on operating conditions.
CYCLE TIMES
Freeze Time + Harvest Time = Total Cycle Time
24 HOUR ICE PRODUCTION
OPERATING PRESSURES
Air Temp.
Entering
Condenser
°F/°C
Freeze Time
Harvest
Time
1
1 Times in minutes
Water Temperature °F/°C
50/10 70/21 90/32
70/21 9.4-10.8 10.4-11.8 11.8-13.4
0.75-2.0
80/27 10.4-11.8 11.4-13.0 13.6-15.5
90/32 11.1-12.6 13.6-15.5 14.7-16.7
100/38 12.5-14.2 16.5-18.7 16.1-18.2
110/43 14.1-16.0 20.9-23.6 16.4-18.6
Air Temp. Entering
Condenser
°F/°C
Water Temperature °F/°C
12
1 Base on average ice slab weight of 10.25 - 11.50lb
2 230/50/1 is approximately 12% lower than 230/60/1
50/10 70/21 90/32
70/21 1350 1245 1110
80/27 1245 1145 975
90/32 1175 975 910
100/38 1055 820 840
110/43 945 660 825
Air Temp.
Entering
Condenser
°F/°C
Freeze Cycle Harvest Cycle
Discharge
Pressure
PSIG
Suction
Pressure
PSIG
Discharge
Pressure
PSIG
Suction
Pressure
PSIG
1
1 Suction pressure drops gradually throughout the freeze cycle
50/10 220-280 40-24 150-180 70-90
70/21 220-280 40-26 160-180 70-90
80/27 240-290 50-27 160-180 70-90
90/32 260-330 50-27 180-200 80-100
100/38 300-370 54-28 200-220 90-115
110/43 330-410 60-29 220-250 100-130