How many operations can be done simultane-
ously?
Two functions can be activated at the same time. However, a single
flow control is used to supply both functions. The single flow control
allows the function operating at the lower pressure to take priority. In
some cases, the function demanding the higher pressure will remain
stationary until the lower pressure function reaches the end of stroke or
is deactivated.