Electrical Requirements
Voltage
The maximum allowable voltage variation is +10/-0%
of the rated voltage on the ice machine model/serial
number plate at start-up (when the electrical load is
highest).
Fuse/Breaker
A separate fuse/circuit breaker must be provided for
each ice machine.
Total Circuit Ampacity
The total circuit ampacity is used to help select the
wire size of the electrical supply.
The wire size (or gauge) is also dependent upon
location, materials used, length of run, etc., so it must
be determined by a qualified electrician.
NOTE: This table is for reference only. Nameplate
information over rides the information in the table
below.
Electrical Specifications
Ice Machine
Voltage
Phase Cycle
Maximum.
Fuse/
Circuit
Breaker
Total
Amps
Q210 230/1/50 15 amp 3.6
Q270 230/1/50 15 amp 5.2
* Indicates Preliminary Data
All wiring must conform to local, state and national
codes and the appliance must be grounded.