68 Part Number STH039 8/13
Suction temperature Low Checklist
Improper Installation
Refer to “Installation and Visual Inspection
Checklist” on page 52.
Discharge temperature
Discharge temperature is too low, and is affecting
suction temperature, refer to “Freeze Cycle
Discharge temperature Low Checklist”
Improper Refrigerant Charge
Undercharged
Wrong type of refrigerant
Other
Non-Manitowoc components in system
Improper water supply over evaporator refer to
“Water System Checklist” on page 53.
Loss of heat transfer from tubing on back side of
evaporator
Restricted/plugged liquid line drier
Restricted/plugged tubing in suction side of
refrigeration system
TXV starving
NOTE: Do not limit your diagnosis to only the items
listed in the checklists.