EasyManua.ls Logo

Manitowoc Q450 - Self-Contained Water-Cooled

Manitowoc Q450
179 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
–135–
Q800 Series - Self-Contained Water-Cooled
Characteristics may vary depending on operating conditions.
CYCLE TIMES
Freeze Time + Harvest Time = Total Cycle Time
24 HOUR ICE PRODUCTION
CONDENSER WATER CONSUMPTION
OPERATING PRESSURES
Air Temp.
Around Ice
Machine
°F/°C
Freeze Time
Harvest
Time
Times in minutes
Water Temperature °F/°C
50/10.0 70/21.1 90/32.2
70/21.1 8.7-10.1 9.5-11.0 10.9-12.5
1-2.5
80/26.7 8.9-10.2 9.7-11.1 11.0-12.7
90/32.2 9.0-10.3 9.8-11.3 11.2-12.9
100/37.8 9.1-10.5 10.0-11.5 11.4-13.1
Air Temp. Around Ice
Machine °F/°C
Water Temperature °F/°C
Based on average ice slab weight of 5.75 - 6.50 lb.
Regular cube derate is 7%
50/10.0 70/21.1 90/32.2
70/21.1 810 750 670
80/26.7 800 740 660
90/32.2 790 730 650
100/37.8 780 720 640
Air Temp. Around Ice
Machine 90°F/32.2°C
Water Temperature °F/°C
Water regulating valve set to maintain 230 PSIG discharge pressure
50/10.0 70/21.1 90/32.2
Gal/24 hours 640 1420 6000
Air Temp.
Around
Ice
Machine
°F/°C
Freeze Cycle Harvest Cycle
Discharge
Pressure
PSIG
Suction
Pressure
PSIG
Discharge
Pressure
PSIG
Suction
Pressure
PSIG
Suction pressure drops gradually throughout the freeze cycle
50/10.0
225-235 33-20 160-185 65-85
70/21.1 225-235 34-20 165-185 70-85
80/26.7 225-235 34-20 165-185 70-85
90/32.2 225-235 36-22 165-185 70-85
100/37.8 225-235 36-22 165-185 70-85
110/43.3 225-240 38-24 170-190 75-90