EasyManua.ls Logo

Manitowoc Q450 - Self-Contained Water-Cooled

Manitowoc Q450
179 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
–141–
Q1300 Series - Self-Contained Water-Cooled
Characteristics may vary depending on operating conditions.
CYCLE TIMES
Freeze Time + Harvest Time = Total Cycle Time
24 HOUR ICE PRODUCTION
CONDENSER WATER CONSUMPTION
OPERATING PRESSURES
Air Temp.
Around Ice
Machine
°F/°C
Freeze Time
Harvest
Time
Times in minutes
Water Temperature °F/°C
50/10.0 70/21.1 90/32.2
70/21.1 9.0-10.1 9.8-10.9 11.4-12.6
1-2.5
80/26.7 9.1-10.1 9.8-11.0 11.6-12.9
90/32.2 9.2-10.3 10.0-11.2 12.0-13.3
100/37.8 9.4-10.5 10.1-11.3 12.2-13.6
Air Temp. Around
Ice Machine °F/°C
Water Temperature °F/°C
Based on average ice slab weight of 10.0 - 11.0 lb.
Regular cube derate is 7%
50/10.0 70/21.1 90/32.2
70/21.1 1370 1280 1120
80/26.7 1360 1270 1100
90/32.2 1340 1250 1070
100/37.8 1320 1240 1050
Air Temp. Around Ice
Machine 90°F/32.2°C
Water Temperature °F/°C
Water regulating valve set to maintain 230 PSIG discharge pressure
50/10.0 70/21.1 90/32.2
Gal/24 hours 1150 2220 7400
Air Temp.
Around Ice
Machine
°F/°C
Freeze Cycle Harvest Cycle
Discharge
Pressure
PSIG
Suction
Pressure
PSIG
Discharge
Pressure
PSIG
Suction
Pressure
PSIG
Suction pressure drops gradually throughout the freeze cycle
50/10.0
235-245 40-18 150-180 70-80
70/21.1 235-245 40-18 150-180 70-80
80/26.7 235-245 40-20 150-180 70-80
90/32.2 235-250 42-20 150-180 70-80
100/37.8 235-255 44-20 150-180 70-80
110/43.3 240-265 46-20 150-180 70-80

Table of Contents

Related product manuals