–5–
Installation
LOCATION OF ICE MACHINE
The location selected for the ice machine head section
must meet the following criteria. If any of these criteria
are not met, select another location.
The location must be free of airborne and other
contaminants.
The air temperature must be at least 35°F (1.6°C),
but must not exceed 110°F (43.4°C).
The location must not be near heat-generating
equipment or in direct sunlight.
The location must not obstruct air flow through or
around the ice machine. Refer to chart below for
clearance requirements.
The ice machine must be protected if it will be
subjected to temperatures below 32°F (0°C). Failure
caused by exposure to freezing temperatures is not
covered by the warranty. See “Removal from
Service/Winterization
ICE MACHINE HEAD SECTION CLEARANCE
REQUIREMENTS
Q1600 is not available as an air-cooled model.
Q370
Self-Contained
Air-Cooled
Water-Cooled
Top/Sides 12" (30.5 cm) 5" (12.7 cm)
Back 5" (12.7 cm) 5" (12.7 cm)
Q1300 Q1600
Q1800
Self-Contained
Air-Cooled
Water-Cooled
and Remote
Top/Sides 24" (61 cm) 8" (20.3 cm)
Back 12" (30.5 cm) 5" (12.7 cm)
All other
Q models
Self-Contained
Air-Cooled
Water-Cooled
and Remote
Top/Sides 8" (20.3 cm) 5" (12.7 cm)
Back 5" (12.7 cm) 5" (12.7 cm)