–73–
4. Compare the results of step 3 with step 2. Ice
production checks that are within 10% of the chart
are considered normal. This is due to variances in
water and air temperature. Actual temperatures will
seldom match the chart exactly. If they match
closely, determine if:
Another ice machine is required.
More storage capacity is required.
Relocating the existing equipment to lower the load
conditions is required.
Contact the local Manitowoc Distributor for information
on available options and accessories.
Installation/Visual Inspection Checklist
Possible Problem List
Corrective Action List
Ice machine is not level
Level the ice machine
Condenser is dirty
Clean the condenser
Water filtration is plugged (if used)
Install a new water filter
Water drains are not run separately and/or are not
vented
Run and vent drains according to the Installation
Manual
Line set is improperly installed
Reinstall according to the Installation Manual