EasyManua.ls Logo

Manitowoc S - Page 152

Manitowoc S
168 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Refrigeration System Section 7
7-46
Part Number 80-1480-3
S1800 SERIES
Remote
NOTE: These characteristics may vary depending on
operating conditions.
Cycle Times
Freeze Time + Harvest Time = Total Cycle Time
24 Hour Ice Production
Operating Pressures
Air Temp.
Entering
Condenser
°F/°C
Freeze Time
Harvest
Time
Water Temperature °F/°C
50/10.0 70/21.1 90/32.2
-20/-28.9 to
70/21.1
8.9-9.8 10.0-11.0 10.7-11.7
1-2.5
80/26.7 9.0-9.9 10.1-11.1 10.8-11.9
90/32.2 9.2-10.1 10.1-11.1 10.8-11.9
100/37.8 9.6-10.5 10.0-11.0 11.6-12.7
110/43.3 10.4-11.5 11.5-12.6 12.5-13.7
Times in minutes
Air Temp.
Entering
Condenser
°F/°C
Water Temperature °F/°C
50/10.0 70/21.1 90/32.2
-20/-28.9 to
70/21.1
1800 1630 1540
80/26.7 1780 1620 1520
90/32.2 1750 1610 1520
100/37.8 1690 1630 1430
110/43.3 1570 1440 1340
Based on average ice slab weight of 13- 14.125 lb
Ratings with JC1395 condenser
Air Temp.
Entering
Condenser
°F/°C
Freeze Cycle Harvest Cycle
Discharge
Pressure
PSIG
Suction
Pressure
PSIG
Discharge
Pressure
PSIG
Suction
Pressure
PSIG
-20/-28.9 to
50/10.0
250-220 44-26 110-170 65-85
70/21.1 280-240 50-28 115-180 70-90
80/26.7 290-245 50-28 115-180 70-90
90/32.2 300-250 52-28 120-195 70-90
100/37.8 340-260 60-28 125-210 70-90
110/43.3 390-295 60-30 125-220 80-100
Suction pressure drops gradually throughout the freeze cycle

Table of Contents